  rev. 8.11.09_141 lpt100-m series 1 of 3 embedded power for business-critical continuity lpt100-m series 130 watts special features ? medical and ite safeties ? active power factor correction ? 2 x 4 footprint ? less than 1u high ? en61000-3-2 compliant ? remote sense ? power fail ? adjustable main output ? built-in class b emi filter ? overvoltage protection ? overload protection ? thermal overload protection ? lpx50 enclosure kit available total power: 80 - 130 watts input voltage: 90 - 264 vac # of outputs: triple electrical specifications safety input input range: 90 - 264 vac; 127 - 300 vdc frequency: 47 - 63 hz inrush current: 50 a max., cold start @ 25 c efficiency: 82% typical at full load emi/rfi: fcc class b conducted; cispr22 class b conducted; en55022 class b conducted; vde0878pt3 class b conducted safety ground leakage current: 275 a @ 50/60 hz, 264 vac input output maximum power: 80 w for convection; 130 w with 200 lfm forced air adjustment range: all outputs adjustable - 40%, +10%, except for +24v output on lpt104-xxx which will be -10%, +20%. hold-up time: 10 ms @ 130 w load, 120 vac input overload protection: short circuit protection on all outputs. case overload protected @ 110 - 160% above rating for v1 & v2, 110-190% for v3 overvoltage protec tion: 15 - 35% above nominal output logical control power failure: active lowttl logic signal goes high 100 - 500 msec after main output; it goes low at least 6 msec before loss of regulation remote sense: compensates for 0.5 v lead drop min. will operate without remote sense connected. reverse connection protected. ? tuv 60950, 60601-1 ? ul 60950, 60601-1 ? csa 60950, 60601-1 ? nemko 60950, 60601-1 ? austel 60950, 60601-1 ? cb certificate & report ? ce mark (lvd)
embedded power for business-critical continuity mechanical drawing rev. 8.11.09_141 lpt100-m series  of 3 operating temperature: 0 to 50 c ambient derate each output as 2.5% per degree from 50 to 70 c. -20 c start up storage temperature: -40 c to +85 c electromagnetic susceptibility: designed to meet en61000-4; -2, -3, -4, -5, -6, -8, -11 level 3 humidity: operating; non-condensing 10% to 95% rh vibration: iec68-2-6 to the levels of iec721-3-2 mtbf demonstrated > 550,000 hours at full load and 25 c ambient conditions environmental specifications sk3 sk2 pin 1 (live) pin 3 (neutral ) sk1 gnd output vo ltag e ad just po ts output vo ltag e ad just po ts mounting hole ? 0.16? [4.0] 4 places max. screw head diameter .22 ? (5.6 ) 0.197? (5.0) m inimum standoff heigh t 2.00? (50.8) 3.73? (94.6) 4.00? (101.6) 1.72? (43.8) 1.28? (32.7) 0.10? (2.5)
rev. 8.11.09_141 lpt100-m series 3 of 3 embedded power for business-critical continuity ordering information model number output voltage minimum load maximum load with convection cooling maximum load with 30cfm forced air peak load regulation 2 ripple p/p (pard) 3 LPT101-M +3.3 v 0 a 13 a 18 a 20 a 2% 50 mv +5 v 0 a 5 a 9 a 10 a 5% 50 mv +12 v 0 a 1 a 2.3 a 2.3 a 5% 120 mv lpt102-m +5 v 0 a 13 a 18 a 20 a 2% 50 mv +12 v 0 a 5 a 9 a 10 a 5% 120 mv -12 v 0 a 1 a 1.5 a 2 a 5% 120 mv lpt103-m +5 v 0 a 13 a 18 a 20 a 2% 50 mv +15 v 0 a 4 a 7.2 a 8 a 5% 150 mv -15 v 0 a 1 a 1.5 a 2 a 5% 150 mv lpt104-m +5 v 0 a 13 a 18 a 2 a 2% 50 mv +24 v 0 a 1.5 a 3 a 3.5 a 7% 240 mv +12 v 0 a 1 a 1.5 a 2 a 5% 120 mv 1. peak current lasting < 15 seconds with a maximum 10% duty cycle. 2 . at 25 c including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3 . peak-to-peak with 20 mhz bandwidth and 10 f (tantalum capacitor) in parallel with a 0.1 f capacitor at rated line voltage and load ranges. notes: 1. specifications subject to change without notice. 2. all dimensions in inches (mm), tolerance is .02. 3. mounting holes mh1, mh2, mh3 should be grounded for emi purpose 4. mounting mh1 is safety ground connection 5. specifications are for convection rating at factory settings at 115 vac input 25 c unless otherwise stated. 6. this power supply requires mounting on metal standoffs 0.20 (5 m) in height. 7. warranty: 2 year 8. weight: 0.44 lb. / 0.20 kg americas 5810 van allen way carlsbad, ca 92008 usa telephone: +1 760 930 4600 facsimile: +1 760 930 0698 europe (uk) waterfront business park merry hill, dudley west midlands, dy5 1lx united kingdom telephone: +44 (0) 1384 842 211 facsimile: +44 (0) 1384 843 355 asia (hk) 14/f, lu plaza 2 wing yip street kwun tong, kowloon hong kong telephone: +852 2176 3333 facsimile: +852 2176 3888 for global contact, visit: www.powerconversion.com techsupport.embeddedpower @emerson.com while every precaution has been taken to ensure accuracy and completeness in this literature, emerson network power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. emerson network power and the emerson network power logo are trademarks and service marks of emerson electric co. ?2009 emerson electric co. emersonnetworkpower.com embedded computing embedded power monitoring outside plant power switching & controls precision cooling racks & integrated cabinets services surge protection emerson network power. the global leader in enabling business-critical continuity. ac power connectivity dc power pin assignments connector lpt100-m sk1 pin 1 neutral pin 3 line sk2 pin 1 v1out pin 2 v1out pin 3 gnd pin 4 gnd pin 5 gnd pin 6 gnd pin 7 v2out pin 8 v3out sk3 pin 1 power fail pin 2 gnd pin 3 + remote sense pin 4 - remote sense mating connectors ac input (sk1): molex p/n 09-50-8031 pins: 08-52-0113 ac ground: molex p/n 01-9002001 dc output (sk2): jst p/n vhr-8n pins: svh-21t-p1.1 remote sense (sk3): molex p/n 87639-0400 pins: 50212-8100 emerson network power connector kit #70-841-026, includes all of the above


▲Up To Search▲   

 
Price & Availability of LPT101-M

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X